Baufragen.de Profi Chat

Examples of design

Example for floor construction with building sealing by customer acc. to DIN 18195 with aquatherm orange system-system element insulation roll 35-3.

1 Waterproofing of buildings DIN 18195 5 Cement screed
2 Edge insulation (min. 8mm thickness) 6 Insulation roll 35-3 resp. 30-2
3 Welded-on PE foil of the edge insulation 7 Additional insulation
4 Heating pipe 8 Concrete
       

Example for floor construction with building sealing by customer acc. to DIN 18195 and additional sealing against surface water (baths, shower, etc.) acc. to DIN 19337 (sealing above the heating surface), with aquatherm orange system-system element knob plate F ND 35-3.

9 Sealing against surface water according to DIN 18337
Search & Find  
advanced search  

517efb111